1 General

1.1 PRONETA Basic and PRONETA Professional

PRONETA Professional is a commercial, licensed software product distributed by SIEMENS. It contains the functionality of PRONETA Basic and furthermore provides additional functions.

1.2 Features

Obtaining PRONETA Basic

PRONETA Basic is available as a free download from the SIEMENS support portal:

https://support.industry.siemens.com/cs/ww/en/view/67460624

This manual refers to version 3.9.

System Requirements

PRONETA Basic runs on any contemporary PC, PG or laptop with Windows 7, Windows Embedded Compact 7, Windows 8, Windows 10 or Windows 11 each either in the 32 or 64-bit version.

Connection with PROFINET is established via an Industrial Ethernet cable.

The following additional software components are also required:

.NET Framework v4.8
If .NET is missing on your PC, the installer will guide you to a download location.

Microsoft Visual C++ Redistributable

An API ("Application Programming Interface") for capturing network traffic, such as Npcap.
Npcap is part of the PRONETA Basic distribution and will be installed at the first start of PRONETA Basic, if there is no Windows Packet Capture Library & Driver on the target PC.

NOTE

  • Depending on the distribution, the .NET Framework and Npcap drivers may not be included in the standard installation for Windows Embedded and may thereforerequire manual installation.
  • The 32-bit version of Microsoft Visual C++ must be used even with 64-bit versions of Windows.

Supported SIMATIC Software

PRONETA Basic allows the loading of reference projects created with STEP 7 Version 5.4 and higher. It is also possible to import AML ("Automation Markup Language") files created with the TIA Portal.

Port information for firewall for scanning

PRONETA Basic uses port 161 for SNMP (Simple Network Management Protocol) and port 34964 for DCE/RPC.

Limitations

The maximum size of a network for which network scans will be reliably performed is 500 devices. For larger networks, devices may go undetected, or PRONETA Basic may crash. (See also Online Mode)

In the IO Test, signal changes of less than 128 ms duration may not be reliably observed. (See also IO Test)

1.3 Supported Devices and Modules

PRONETA Basic supports all PROFINET-conform devices irrespective of their manufacturer. The supported range of functions depends on the individual device.

The IO Test supports the following devices and modules:

Most current SIMATIC ET 200 modules, including ET 200SP, ET 200M, ET200MP, ET200pro and ET200ecoPN.

SIMATIC IO-Link modules (Master/Device)

SIMATIC Compact Field Units (CFU)

SIRIUS Motor Starters with Firmware Versions 1.1 or greater

SIPLUS Heating Control Systems HCS4200/4300

Most SIMATIC S7-1500 CPUs, including S7-1500 Advanced Controllers, and Drive Controller CPUs 1504D TF and 1507D TF.

Reference List

A continuously updated list of supported modules for PRONETA Basic can be found on the PRONETA Basic download page

Updating the PRONETA Basic GSDML database

Modules can subsequently be supported by importing their GSDML file from the SIEMENS Industry Online Portal web pages, provided they do not require any new functionality. See the GSDML Manager section for more details.

1.4 Seting up and Running PRONETA Basic

Setup

Extract the PRONETA Basic file archive into a folder on your PC, and connect your PC by means of an Industrial Ethernet cable with your plant.

No further installation is required for PRONETA Basic.

 

NOTE

The extraction path for PRONETA Basic must not contain either of the special characters "#" or ";".

To perform IO Tests (see IO Test Task), PRONETA Basic must be placed in a directory where it will have writing privileges during execution.

Starting PRONETA Basic

After setup, you can start PRONETA Basic by a double-click on the program icon in the extraction folder.

NOTE

 

You may also create a shortcut link to PRONETA Basic on your desktop and start the program from there.

Quitting PRONETA Basic

To quit PRONETA Basic, click on the "Close"-icon of the program’s window.

Removing PRONETA Basic from your system

If you do not plan to use PRONETA Basic any further, perform the two following steps:

1.      Delete the folder to which you extracted PRONETA Basic,

2.      Open Device Manager, navigate to Network adapters. Right-click the Npcap Loopback Adapter Driver and select "Uninstall device".